Employers that use boilers, steam plant or compressed air need to know which equipment counts as a pressure system, who holds the duties, the safe operating limits, the written scheme of examination and the role of the competent person. This guide explains each, with protective devices, training and records. It is general information, not technical advice.

Most FM leaders can name the boilers, calorifiers and compressors on their sites. Fewer can say at a glance which of them count as pressure systems, who is responsible for each and when each was last examined. HSE says that if pressure equipment fails in use, it can seriously injure or kill people nearby and cause serious damage to property, and that the regulations aim to prevent serious injury from the stored energy.
This guide explains why pressure systems are a leadership issue, what counts as a pressure system, who holds the duties, safe operating limits, the written scheme of examination, the competent person, protective devices and maintenance, instructions, training and records, and repairs and contractors. It draws on guidance from the Health and Safety Executive (HSE), its leaflets and the Pressure Systems Safety Regulations.
The core idea: Know which of your systems are pressure systems, who is responsible for each, and that the examinations and records are up to date.
What the guide covers
- Why Pressure Systems Are a Leadership Issue
- What Counts as a Pressure System
- Who Holds the Duties
- Safe Operating Limits
- The Written Scheme of Examination
- The Competent Person
- Protective Devices and Maintenance
- Instructions, Training and Records
- Repairs, Modifications and Contractors
- Common Mistakes
Why Pressure Systems Are a Leadership Issue
HSE says the hazards of pressure equipment include blast from an explosion or the release of compressed liquid or gas, impact from failed parts or flying debris, contact with released liquid or gas such as steam, and fire from escaping flammable liquids or gases.
In practice: Ask your team for a list of every pressure system on one site, with the date of its last examination.
What Counts as a Pressure System
HSE describes a pressure system as one or more rigid pressure vessels with associated pipework and protective devices. It says a system counts if it contains, or is likely to contain, a relevant fluid: steam at any pressure, compressed or liquefied gas including air above half a bar above atmospheric pressure, pressurised hot water above one hundred and ten degrees Celsius, or acetylene and other gases dissolved under pressure. HSE says hydraulic oils are excluded.
In practice: Walk one plant room and note every vessel, boiler or compressor, with its fluid and its working pressure.
Who Holds the Duties
HSE says the duties fall on owners of mobile systems, such as a compressor moved between sites, and users of installed systems, such as a steam boiler. It says users of hired or leased equipment need to confirm that a written scheme of examination is in place and that the examination certificate is current. HSE’s leaflet on written schemes says the legal responsibility for defining the scope of the scheme rests with users or owners.
In practice: For each system on your list, write down who is the user or owner and where that is recorded.
Safe Operating Limits
Regulation seven of the Pressure Systems Safety Regulations, in its original form, says the user of an installed system and the owner of a mobile system shall not operate it, or allow it to be operated, until the safe operating limits have been established. Where the owner of a mobile system is not the user, the owner needs to give the user a written statement of the limits or make sure they are marked on the system.
In practice: Pick one boiler or air receiver and find where its safe operating limits are recorded.
The Written Scheme of Examination
HSE says that before qualifying equipment is used, a written scheme of examination needs to be in place and an examination carried out. It says the scheme covers the protective devices, pressure vessels and pipework whose failure could be dangerous, and that a competent person draws it up or certifies it.
In practice: Ask to see the written scheme for one system and check who certified it and when it was last reviewed.
The Competent Person
HSE says a competent person carries out the examinations under the written scheme. The competent person reviews the scheme, writes a report, tells the user or owner what repairs are needed, acts on imminent danger and agrees any postponement. HSE says the competent person needs to be independent of operational functions and to have the authority to stop equipment being used.
In practice: Find out who examines your systems, who they report to and whether they can stop a system being used.
Protective Devices and Maintenance
HSE says users need to fit suitable protective devices such as safety valves, bursting discs and electronic protection, set them correctly and keep them working. HSE’s brief guide says to ensure that, once set, protective devices cannot be altered except by an authorised person.
In practice: Look at the last year of maintenance records for one system and check for repeated safety valve discharges.
Instructions, Training and Records
The original regulations say the user of an installed system and the owner of a mobile system need to give anyone who operates it adequate and suitable instructions on running it safely and on what to do in an emergency, and that nobody should run it except in line with them. HSE says anyone who operates, installs, maintains, repairs, inspects or tests the equipment needs to be competent, with refresher training.
In practice: Ask for the last examination report and the operating instructions for one system and see how long they take to find.
Repairs, Modifications and Contractors
HSE says to take care with repairs and modifications and to consider re-examining the whole system afterwards, and to plan and record modifications so they do not create danger. HSE’s brief guide says that after a major repair or modification you may need to have the whole system re-examined before it comes back into use. The original regulations say an employer whose worker modifies or repairs a pressure system needs to make sure nothing about the way it is done gives rise to danger.
In practice: Check whether your permit or change process asks whether the work touches a pressure system.
Common Mistakes
- Not knowing which systems count as pressure systems
- Assuming a contractor or landlord holds the duty without confirming it in writing
- Operating or hiring out equipment before the written scheme and examination are in place
- Treating examination as a substitute for routine maintenance
- Appointing a competent person without checking knowledge, experience and independence
- Letting protective devices be adjusted by people who are not authorised
- Ignoring a safety valve that repeatedly discharges
- Changing pipework or controls without a planned, recorded change
Most of these are avoidable. Keep a simple register, check it regularly and ask the competent person about anything that changes.
Frequently asked questions
What counts as a pressure system?
HSE says it is a system of vessels, pipework and protective devices holding steam at any pressure, gas above half a bar, or hot water above one hundred and ten degrees Celsius.
Who holds the duties?
HSE says users of installed systems and owners of mobile systems. Users of hired or leased equipment need to confirm the scheme is in place and the certificate is current.
Do we need a written scheme of examination?
HSE says one needs to be in place, and an examination carried out, before qualifying equipment is used. A competent person draws it up or certifies it.
Who can be the competent person?
HSE’s brief guide says an in-house inspection department, an individual or an independent inspection body, if you are satisfied they have knowledge, experience and independence.
Does an examination replace maintenance?
No. HSE says examination does not replace routine maintenance, and compares it to an MOT for a car. Systems need a maintenance programme for the whole system.
Can we operate a system before the scheme exists?
HSE’s brief guide says not to allow a pressure system to be operated, or hired out, until you have a written scheme of examination and the system has been examined.
What should we keep on record?
The regulations as made say to keep the latest examination report, earlier reports that would help show it is safe to operate or repair, and the information supplied with the system.
What if a safety valve keeps lifting?
HSE’s brief guide says repeated discharge could mean the system is overpressurising or the safety valve is not working correctly, so investigate it rather than ignore it.
Key takeaways
- HSE says relevant fluids include steam at any pressure, compressed or liquefied gas above half a bar and pressurised hot water above one hundred and ten degrees Celsius
- HSE says the duties fall on users of installed systems and owners of mobile systems, and users of hired or leased equipment need to confirm that the written scheme is in place and the certificate is current
- HSE says a written scheme of examination needs to be in place and an examination carried out before qualifying equipment is used, and a competent person draws up or certifies the scheme
- HSE says the competent person needs to be independent of operational functions and have the authority to stop equipment being used
- HSE says examination does not replace routine maintenance, and users need operating instructions, protective devices set correctly and competent people to run the system
Final thoughts
Pressure systems stay safe when the basics are done reliably: a list of what you have, a named user, safe limits that are written down, a current examination scheme, an independent competent person and records that can be found. HSE’s guidance gives leaders a practical way to check each of them.
Identify your systems, settle who is responsible, check the written scheme and reports, look after protective devices, and plan repairs and modifications. Take advice from a competent person on the detail.
Related reading
- Safety and Compliance Leadership in FM: Who Owns the Duty
- Managing Contractors and Suppliers: The Leader's Role
- Building Operational Resilience in FM
- Browse the full Insights library
Who this resource is for
FM Directors, Heads of Facilities, engineering and operations managers, and health and safety leads who are responsible for boilers, steam plant, compressed air systems and the contractors who service them.
Talk to Maxwell Stephens
If you want to talk this through, contact Maxwell Stephens or call 0207 118 4848 to book a scoping call.
For help defining and filling a senior role, explore our Facilities Director recruitment service.
Last reviewed 29 November 2026. Laws, dates and figures change, so check the current position before you act. This resource is general information, not legal advice.