In brief

Employers need to make sure enclosed workplaces have adequate ventilation. This guide explains what the law says, how to assess poorly ventilated areas, natural and mechanical ventilation, carbon dioxide monitors, temperature and draughts, sick building symptoms, and maintenance. It is general information, not technical advice, and it does not cover harmful fumes or dust from work processes.

Indoor air quality: a guide for FM leaders cover

People notice air before they notice almost anything else about a building. A room that feels stuffy, a smell that lingers or a draught on the back of the neck soon becomes a complaint, and complaints about air often land on the FM team. Behind them sit a legal duty and a set of systems that FM leaders own: windows, vents, fans, ducts, filters and the people who maintain them.

This guide explains why indoor air quality is a leadership issue, what the law says about ventilation, how to assess the risk of poor ventilation, natural and mechanical ventilation, carbon dioxide monitors, comfort, temperature and draughts, sick building symptoms, and maintenance and records. It draws on guidance from the Health and Safety Executive (HSE), the regulation on ventilation and the NHS.

The core idea: Know which areas of your buildings are poorly ventilated, keep the systems that supply fresh air working, and treat complaints about air as information to act on.

What the guide covers

  • Why Indoor Air Quality Is a Leadership Issue
  • What the Law Says
  • Assessing the Risk of Poor Ventilation
  • Natural Ventilation
  • Mechanical Ventilation and Air Conditioning
  • Using Carbon Dioxide Monitors
  • Comfort, Temperature and Draughts
  • Spotting Sick Building Symptoms
  • Maintenance, Cleaning and Records
  • Common Mistakes

Why Indoor Air Quality Is a Leadership Issue

HSE says good ventilation is associated with improved health, better concentration, higher levels of satisfaction with an environment, lower rates of absence from work, better quality of sleep and reduced exposure to a wide range of air pollutants.

In practice: Check that someone owns ventilation across your sites, and that they know what the duty and the systems involve.

What the Law Says

HSE’s ventilation guidance opens by saying employers need to make sure there is adequate ventilation in enclosed areas of their workplace. It cites regulation six of the Workplace (Health, Safety and Welfare) Regulations, which says effective and suitable provision shall be made to ensure that every enclosed workplace is ventilated by a sufficient quantity of fresh or purified air.

In practice: Find out which ventilation plant on your sites has a failure warning, and who receives it.

Assessing the Risk of Poor Ventilation

HSE says your workplace risk assessment should identify poorly ventilated work areas, including changing rooms and areas used for breaks, such as canteens. It suggests looking for areas where there is no natural ventilation, such as open windows, doors or vents, and areas that feel stuffy or smell bad, and considering a carbon dioxide monitor.

In practice: List the areas on one site and note how each is ventilated, using floor plans if that helps.

Natural Ventilation

HSE describes natural ventilation as relying on doors, windows and other openings, such as trickle vents, air bricks or grilles, to provide air. It says you can improve it by fully or partly opening windows, air vents and doors, but that fire doors should not be propped open. Any windows that have been painted shut should be reopened.

In practice: On a site visit, check that windows and vents open as designed and that no fire doors are propped open.

Mechanical Ventilation and Air Conditioning

HSE says mechanical ventilation uses fans to move air into and out of rooms, and that larger buildings may use a network of ducts and fans to blow clean air in and extract stale air. It says to speak to the people who manage the day-to-day operation of these systems and to make sure they are maintained in line with the manufacturers’ instructions.

In practice: Speak to the person who runs one system day to day and ask how fresh air reaches each area.

Using Carbon Dioxide Monitors

HSE says carbon dioxide monitors can help you identify poor ventilation so you can improve it, and that the most appropriate portable devices for the workplace are non-dispersive infrared monitors. It says to place them at head height, away from windows, doors and air supply openings, and over half a metre from people, because exhaled breath contains carbon dioxide.

In practice: Take several readings across a day in one busy room and note what the ventilation was doing at the time.

Comfort, Temperature and Draughts

HSE’s ventilation guidance says businesses need to ensure workplace temperatures are reasonable. It gives no minimum or maximum temperature and points to its separate guidance on keeping a comfortable temperature at work. It says workers should not be exposed to uncomfortable draughts.

In practice: Look at the last three months of temperature and air complaints and check whether they cluster in particular rooms.

Spotting Sick Building Symptoms

The NHS says sick building syndrome is the name for symptoms you get while you are in a particular building. It usually happens in an office, mostly an open-plan one, and the symptoms get worse the longer you are there and get better after you leave.

In practice: Where several people report similar symptoms in one area, note where and when, and check the ventilation and cleaning there.

Maintenance, Cleaning and Records

HSE says mechanical ventilation should be maintained in line with the manufacturers’ instructions, and the ventilation regulation expects plant to include a failure warning where necessary for health or safety. The NHS lists poorly maintained air conditioning and problems with cleaning and layout among the possible causes of sick building symptoms.

In practice: Choose one ventilation system and see whether you can answer each point on that list from your records.

Common Mistakes

  • Treating complaints about stuffy rooms as comfort issues rather than ventilation signals
  • Leaving windows painted shut, or vents blocked or closed
  • Propping fire doors open to improve airflow
  • Relying on desk or ceiling fans in poorly ventilated areas
  • Assuming outdoor air is clean and that systems bring in fresh air
  • Taking one carbon dioxide reading and treating it as proof
  • Missing break areas and changing rooms in the assessment
  • Maintaining systems without checking the manufacturers’ instructions

Most of these are avoidable. Walk the spaces, talk to the people in them and keep simple records.

Frequently asked questions

What does the law say about ventilation at work?

Regulation six of the Workplace (Health, Safety and Welfare) Regulations says every enclosed workplace is to be ventilated by a sufficient quantity of fresh or purified air.

Does HSE set a fresh-air rate?

HSE says the supply rate should not normally fall below five to eight litres per second per occupant, and that ten is recommended in some building guides.

How do we find poorly ventilated areas?

Look for areas without natural ventilation and areas that feel stuffy or smell bad, and consider a monitor. HSE says to include break areas and changing rooms.

Are desk fans enough in a stuffy room?

No. HSE says not to rely purely on desk or ceiling fans in poorly ventilated areas, as they will not improve ventilation. They can help people feel cooler where ventilation is adequate.

What carbon dioxide level shows poor ventilation?

HSE says levels consistently above one thousand five hundred parts per million in an occupied room indicate poor ventilation, but readings are only a broad guide to ventilation.

Who maintains mechanical ventilation?

HSE says to speak to the people who run the systems day to day and make sure they are maintained in line with the manufacturers’ instructions. A ventilation engineer may be needed.

What is sick building syndrome?

The NHS describes symptoms you get while in a particular building, such as headaches and tiredness, that get worse the longer you are there and improve after you leave.

What should we do if people report symptoms?

The NHS says employers and building managers should look into the problem and try to find a solution. HSE has guidance for employers and building managers on investigating it.

Key takeaways

  • HSE says employers need to make sure there is adequate ventilation in enclosed areas of the workplace, and regulation six calls for every enclosed workplace to be ventilated by a sufficient quantity of fresh or purified air
  • HSE says a workplace risk assessment should identify poorly ventilated areas, including changing rooms and break areas, and that talking with workers helps
  • HSE says mechanical ventilation should be maintained in line with the manufacturers’ instructions, fresh-air inlets should be kept open on recirculating systems and a ventilation engineer may be needed
  • HSE says carbon dioxide monitors can help identify poor ventilation, but readings are only a broad guide and not a measure of safe levels
  • The NHS says sick building syndrome is the name for symptoms you get while you are in a particular building, and that employers and building managers should look into reports and try to find a solution

Final thoughts

Good indoor air is mostly the result of ordinary things done reliably: windows that open, fresh-air inlets that stay clear, systems that are maintained and complaints that are taken seriously. HSE’s guidance gives leaders a practical way to check each of them.

Identify poorly ventilated areas, check natural and mechanical ventilation, use monitors with care, manage comfort and draughts, and investigate symptom reports. Take advice from a ventilation engineer or a competent person on the detail.

Related reading

Who this resource is for

FM Directors, Heads of Facilities, engineering and operations managers, and health and safety leads who are responsible for ventilation, air conditioning and the comfort of people in occupied buildings.

Talk to Maxwell Stephens

If you want to talk this through, contact Maxwell Stephens or call 0207 118 4848 to book a scoping call.

For help defining and filling a senior role, explore our Facilities Director recruitment service.

Last reviewed 29 November 2026. Laws, dates and figures change, so check the current position before you act. This resource is general information, not legal advice.